Imprimer

Lecteur de microplaques, Varioskan™ LUX

Fournisseur: Thermo Fisher Scientific
Ratings: Ecrire un avis

Total Evaluation: 0
Moyenne des Notes : 0.0 sur 5

Varioskan™ LUX
735-0309EA 61000 EUR
735-0309 LABLVLBL0TGD2 LABLVLBL0TGD0 LABLVLBL0TGD1 735-0295 735-0296 735-0297 735-0298 735-0310 735-0299 735-0311 735-0312 735-0313 735-0314 735-0315 735-0316 735-0317 735-0318 735-0319 LABLVLBLATGD1 LABLVLBLATGD2 LABLVLBLATGD0 LABLVLB000GD2 LABLVLB000GD0 LABLVLB000GD1 LABLVLBL00GD2 LABLVLBLA0GD0 735-0320 LABLVLBL00GD0 LABLVLBLA0GD2 735-0321 735-0300 LABLVLBL00GD1 735-0322 LABLVLBLA0GD1 735-0301 735-0323 735-0302 735-0324 735-0303 735-0304 735-0305 735-0306 735-0307 735-0308
Lecteur de microplaques, Varioskan™ LUX
Lecteurs de microplaques
Varioskan™ LUX est équipé d'une gamme de technologies de mesure incluant des modules de série pour le calcul de l'absorption, l'intensité de fluorescence et le FRET, des modules en option pour le calcul de luminescence et de fluorescence résolue dans le temps, ainsi que la technologie AlphaScreen.

  • Sélection automatique de gamme dynamique, en fonction de l'intensité du signal de chaque puits
  • Contrôles de sécurité intelligents pour identifier les problèmes potentiels et à alerter l'utilisateur avant qu'ils ne se produisent
  • Étalonnage automatique de l'instrument et auto-diagnostic des performances fiables
  • Contrôle précis de la température pour applications sensibles à la température
  • Module de commande gaz intégré (optionnel) pour le réglage des concentrations de CO₂ et d'O₂ pour les dosages cellulaires
  • Distributeurs (en option) de distribution et mesure simultanées, afin de contrôler les signaux en début de réaction

Logiciel SkanIt disponible en 9 langues :
Interface utilisateur intuitive simple pour la configuration des mesures
Outil Virtual pipette™ pour la disposition des échantillons sur les plaques
Options de calcul intégrées de traitement des données
Exportation de données manuelle ou automatique vers tous les emplacements
L'enregistrement continu des données de mesure dans la base de données permet d'éviter la perte de données due à des interruptions comme des coupures de courant ou des arrêts accidentels
Disponible en deux éditions: Research Edition (fourni) ou Drug Discovery Edition

Absorbance:
Plate types: 6 to 384 well plates
Wavelength selection: Double monochromators
Wavelength range: 200 to 1000 nm
Light source: Xenon flash lamp
Read out range: 0 to 6 Abs
Linear measurement range: 0 to 4 Abs (96-well plate) at 450 nm, ±2%; 0 to 3 Abs (384-well plate) at 450 nm, ±2%
Accuracy: 0,003 Abs or ±2%, at 200 to399 nm (0 to 2 Abs); 0,003 Abs or ±1%, at 400 to 1000 nm (0 to 3 Abs);
Precision: SD <0,001 Abs or CV <0,5%, at 450 nm (0 to 3 Abs)

Fluorescence intensity:
Plate types: 6 to 1536 well plates
Wavelength selection: Double excitation and emission monochromators
Excitation wavelength range: 200 to 1000 nm
Emission wavelength range: 270 to 840 nm
Light source: Xenon flash lamp
Sensitivity: Top reading: <0,4 fmol fluorescein/well (black 384-well plate); Bottom reading: <4 fmol fluorescein/well, (clear bottom black 384-square well plate)
Dynamic range: Top reading >6 decades; Bottom reading >5,5 decades

Time-resolved fluorescence:
Plate types: 6 to 1536 well plates
Wavelength selection: Filters (spectral scanning with double excitation and emission monochromators)
Excitation wavelength range: Fixed to 334 nm (spectral scanning 200 to 840 nm)
Emission wavelength range: 400 to 700 nm (spectral scanning 270 to 840 nm)
Light source: Xenon flash lamp
Sensitivity: <1 amol Eu/well (white low volume 384 well plate)
Dynamic range: >6 decades

Luminescence:
Plate types: 6 to 1536 well plates (spectral scanning 6 to 384 well plates)
Wavelength selection: Direct or filters (spectral scanning with double monochromators)
Wavelength range: 360 to 670 nm
Sensitivity: <7 amol ATP/well (white 384-well plate)
Dynamic range: >7 decades

AlphaScreen:
Plate types: 6 to 1536 well plates
Wavelength selection: Filters
Excitation wavelength range: Fixed to 680 nm
Emission wavelength range: 400 to 660 nm
Light source: LED
Sensitivity: <100 amol phosphotyrosine/well (white 384-well plate)

Dispensing:
Plate types: 6 to 384 well plates
No. of dispensers: None, one or two
Syringe size: 1 ml (standard), 5 ml (optional)
Dispensing volume: 2 to 5000 μl, in 1 µl increments (1 ml syringe); 5 to 25 000 μl, in 5 µl increments (5 ml syringe)
Accuracy: <1 μl with 50 μl (0,4 mm tip), <0,2 μl with 5 μl (0,25 mm tip)
Precision: <1 μl with 50 μl (0,4 mm tip), <0,25 μl with 5 μl (0,25 mm tip)
Dead volume: Reagent loss <100 μl; Total tubing volume <800 μl

Informations de commande: Pour plus d'informations techniques sur l'ensemble des modules disponibles pour le Varioskan® LUX et les distributeurs, incubateurs et agitateurs intégrés, veuillez contacter Avantor.
Commander maintenant

Learn more

About VWR

Avantor is a vertically integrated, global supplier of discovery-to-delivery solutions for...

Plus About VWR